1. Forecast
Solariance-API-V1
  • Getting Started
  • Authentication
  • Time and intervals
  • Data and resolution
  • Changelog
  • Use Solariance in Claude
  • Forecast
    • forecast/power
      GET
    • forecast/energy
      GET
    • forecast/temperature
      GET
    • forecast/export
      GET
    • forecast/correction-factors
      POST
    • forecast/market
      GET
  • System
    • system/list
      GET
    • system/view
      GET
    • system/create
      POST
    • system/update
      PUT
    • system/delete
      DELETE
    • system/forecast_status
      GET
  • User
    • user/view
      GET
    • user/update
      PUT
  • Measured
    • Measured irradiance (not live yet)
    • measured/irradiance/upload (not live yet)
      POST
    • measured/irradiance: read (not live yet)
      GET
    • measured/irradiance: erase (not live yet)
      DELETE
  • Portfolio
    • portfolio/schedule
      GET
    • portfolio/forecast
      GET
  • Schemas
    • IrradianceUploadRequest
    • IrradianceSeries
    • IrradianceValuePair
    • IrradianceSensor
    • IrradianceUploadResponse
    • IrradianceConflictResponse
    • IrradianceUploadData
    • IrradianceTotals
    • IrradianceSeriesResult
    • IrradianceRejection
    • IrradianceWarning
    • IrradiancePreview
    • IrradianceReadResponse
    • ErrorData
    • IrradianceSensorList
    • IrradianceSensorValues
    • IrradianceSensorView
    • IrradianceRow
    • IrradianceEraseResponse
    • ErrorResponse
Impressum
Datenschutz
  1. Forecast

forecast/market

GET
https://api.solariance.de/v1/forecast/market
One system's forecast as feed-in and money: per interval and per day, the energy the system can feed in under its feed-in limit, the DE-LU day-ahead price, the market value and the revenue under the system's own remuneration rule. Use it to see what today's and tomorrow's generation is worth, how much a feed-in limit clips, and what negative prices cost.
Who may call it. Every plan, for the caller's own systems; a ReadOnly API token is enough. days reaches as far as the plan's forecast horizon (Free 2 days, paid plans 5). Budget per hour: the plan's forecast rate (Free and Plus 30, Premium and Premium for Business 500, Enterprise 5,000), counted under its own key, so it does not use up forecast/power. Enterprise contracts can set other limits. A system paused by the plan answers 403 system_locked.
Slots. One slot per row of the newest forecast run: 15 minutes for about the first 48 hours in the high-resolution area, then 60 and 180 minutes (minutes gives each length). A slot covers [start_utc, start_utc + minutes): the label is the START of the interval, in UTC, and start_local is the same instant in the system's time zone with its offset. Days are local calendar days of that time zone (23 or 25 hours on the clock-change days). See Time and intervals.
How each slot is valued.
Potential: power_w is the forecast's mean AC power over the slot, energy_wh that power times the slot's length.
Feed-in limit: the effective limit is the smaller of feed_in_limit_kw and feed_in_limit_pct x kWp, lowered to the inverter's AC rating when that is smaller. Without a declared limit nothing is clipped. Feed-in = energy x min(1, limit / mean power), so the limit caps the slot's mean power: exact on a 15-minute slot, an underestimate of the clipping on a coarser one, which then carries approximate: true. clipped_wh is the difference.
Curtailment at negative prices: only when the system declares curtail_at_negative_price: the share of the slot with a price below zero feeds nothing in (curtailed_wh).
Market value: feed-in x the DE-LU day-ahead price (EUR/MWh), negative when the price is negative. A slot longer than the price unit gets the time-weighted mean price. When curtailing, the negative-price part of the slot earns nothing.
Revenue, only for a declared remuneration_model: market = the market value; feed_in_tariff = feed-in x the stored tariff (EUR/kWh), except that with eeg51_applies (§ 51 EEG) the feed-in during negative prices earns nothing; that amount is unpaid_eur. No model declared, or no tariff stored: revenue_eur is null.
No price (beyond the published auction, or a system outside Germany and Luxembourg): every price and market-value field is null, never 0, and no curtailment is assumed. Tariff revenue is still given when neither eeg51_applies nor curtail_at_negative_price is set, because then the price does not matter. Tomorrow's prices exist once the day-ahead auction is published, usually early in the afternoon; prices_published_until_utc says how far they reach.
The limit, tariff and rules are the system's own declarations (feed_in_limit_kw, feed_in_limit_pct, remuneration_model, eeg51_applies, curtail_at_negative_price, feed_in_tariff), set in the Solariance app or website or with system/create / system/update, and returned by system/view. null means not declared.
Units. Power in W (mean over the slot), energy in Wh per slot and kWh per day, prices in EUR/MWh, money in EUR (4 decimals per slot, 2 per day). A value that cannot be known is null; 0 is a real value.
Assumptions (data.assumptions, stable codes; the first five are always present):
CodeMeaning
no_self_consumptionAll generation is offered to the grid; on-site consumption is not modelled, so feed-in and clipping are upper bounds
no_batteryStorage is not modelled, even when the system declares one
cap_on_slot_mean_powerThe limit caps each slot's mean power: exact on 15 minutes, approximate on coarser slots
day_ahead_pricePrices are the DE-LU day-ahead auction, not intraday or imbalance prices
market_value_excludes_premium_and_feesThe market value is the spot value only: no market premium (Marktprämie), no direct-marketer fees
no_price_zone(forecast/market only) The system is outside Germany and Luxembourg: no prices are applied
remuneration_model_not_declared(forecast/market only) No remuneration_model declared: revenue_eur and unpaid_eur are null; market_value_eur is still given
no_feed_in_tariff_stored(forecast/market only) remuneration_model is feed_in_tariff but no tariff above 0 is stored: revenue is null
No forecast in the window: 204 with no body. Tokens, errors and plans: Authentication.
Day-ahead prices: ENTSO-E Transparency Platform (bidding zone DE-LU).

Request

Authorization
Provide your bearer token in the
Authorization
header when making requests to protected resources.
Example:
Authorization: Bearer ********************
Query Params

Header Params

Request Code Samples

Shell
JavaScript
Java
Swift
Go
PHP
Python
HTTP
C
C#
Objective-C
Ruby
OCaml
Dart
R
Request Request Example
Shell
JavaScript
Java
Swift
curl --location 'https://api.solariance.de/v1/forecast/market?system_id=PVABCDEFGHJK&days=2' \
--header 'Authorization: Bearer <token>'

Responses

🟢200
application/json
The valuation. Example trimmed to three of 186 slots.
Bodyapplication/json

Example
{
    "code": 200,
    "message": "Market valuation of the forecast for system PVABCDEFGHJK",
    "data": {
        "system": {
            "system_id": "PVABCDEFGHJK",
            "name": "My PV system",
            "kwp": 10.32,
            "inverter_ac_kw": 9.6,
            "feed_in_limit_kw": null,
            "feed_in_limit_pct": 70,
            "effective_limit_kw": 7.224,
            "limit_source": "feed_in_limit_pct",
            "remuneration_model": "feed_in_tariff",
            "revenue_basis": "feed_in_tariff",
            "feed_in_tariff_eur_kwh": 0.08,
            "eeg51_applies": false,
            "curtail_at_negative_price": false,
            "price_zone": "DE-LU"
        },
        "time_zone": "Europe/Berlin",
        "days_requested": 2,
        "forecast_issued_utc": "2026-11-18T22:33:49Z",
        "prices_published_until_utc": "2026-11-19T23:00:00Z",
        "assumptions": [
            "no_self_consumption",
            "no_battery",
            "cap_on_slot_mean_power",
            "day_ahead_price",
            "market_value_excludes_premium_and_fees"
        ],
        "slots": [
            {
                "start_utc": "2026-11-19T11:00:00Z",
                "start_local": "2026-11-19T12:00:00+01:00",
                "minutes": 15,
                "power_w": 581.9,
                "feed_in_w": 581.9,
                "energy_wh": 145.5,
                "feed_in_wh": 145.5,
                "clipped_wh": 0,
                "curtailed_wh": 0,
                "price_eur_mwh": 240.22,
                "market_value_eur": 0.0349,
                "revenue_eur": 0.0116,
                "unpaid_eur": 0,
                "negative_price": false,
                "approximate": false
            },
            {
                "start_utc": "2026-11-19T11:15:00Z",
                "start_local": "2026-11-19T12:15:00+01:00",
                "minutes": 15,
                "power_w": 470.1,
                "feed_in_w": 470.1,
                "energy_wh": 117.5,
                "feed_in_wh": 117.5,
                "clipped_wh": 0,
                "curtailed_wh": 0,
                "price_eur_mwh": 227.11,
                "market_value_eur": 0.0267,
                "revenue_eur": 0.0094,
                "unpaid_eur": 0,
                "negative_price": false,
                "approximate": false
            },
            {
                "start_utc": "2026-11-20T11:00:00Z",
                "start_local": "2026-11-20T12:00:00+01:00",
                "minutes": 15,
                "power_w": 1639.8,
                "feed_in_w": 1639.8,
                "energy_wh": 409.9,
                "feed_in_wh": 409.9,
                "clipped_wh": 0,
                "curtailed_wh": 0,
                "price_eur_mwh": null,
                "market_value_eur": null,
                "revenue_eur": 0.0328,
                "unpaid_eur": 0,
                "negative_price": null,
                "approximate": false
            }
        ],
        "days": [
            {
                "date": "2026-11-19",
                "energy_kwh": 3.615,
                "feed_in_kwh": 3.615,
                "clipped_kwh": 0,
                "curtailed_kwh": 0,
                "negative_price_kwh": 0,
                "market_value_eur": 0.89,
                "revenue_eur": 0.29,
                "unpaid_eur": 0,
                "price_coverage": "full"
            },
            {
                "date": "2026-11-20",
                "energy_kwh": 7.1,
                "feed_in_kwh": 7.1,
                "clipped_kwh": 0,
                "curtailed_kwh": 0,
                "negative_price_kwh": null,
                "market_value_eur": null,
                "revenue_eur": 0.57,
                "unpaid_eur": 0,
                "price_coverage": "none"
            }
        ]
    }
}
🟢204
🟠400
🟠401
🟠403
🟠429
🔴500
Modified at 2026-11-19 00:46:28
Previous
forecast/correction-factors
Next
system/list